Reader Directives
The suffixes listed are prefixed by the current <ReaderKeyword> in a mapping file. By default, the <ReaderKeyword> for the Microsoft Excel reader is SXF.
These directives are exposed in Workbench as format settings through the Reader Parameters.
DATASET
This is the SXF file name. Note that if an .RSC file with the same name is present in the same folder, it will be used to determine feature type names, the sxf_object_class_name Format Attribute, and attribute names.
Required/Optional
Required
Mapping File Syntax
SXF_DATASET C:/data/citySource.sxf
Workbench Parameter
Source SXF File
DEF
Required/Optional: Required
Each dataset must be defined before it can be read. The definition contains the worksheet/named range name, followed by the names and types of the attributes.
The syntax of an SXF DEF line is:
SXF_DEF <baseName> \ sxf_type <wkb_type> \ [<attrName> <attrType>]+
RSC_FILENAME
Required/Optional
Optional
Mapping File Syntax
<ReaderKeyword>_RSC_FILENAME <file path>
Workbench Parameter
RSC File
NAMING_SCHEME
Required/Optional
Optional
Mapping File Syntax
<ReaderKeyword>_NAMING_SCHEME [SHORT_NAMES | FULL_NAMES]
Workbench Parameter
Names
IDs
Required/Optional
Optional
This optional specification is used to limit the available and defined SXF layers that will be read. If no layers are specified, then all layers are read.
SXF_IDs <featureType1> \ <featureType2> … \ <featureTypeN>
The feature types must match those used in DEF lines.
The example below selects only the “city” layer for input during a translation:
SXF_IDs city
Mapping File Syntax
<ReaderKeyword>_IDs <featureType1> [<featureTypeN>]*
SEARCH_ENVELOPE
Using the minimum and maximum x and y parameters, define a bounding box that will be used to filter the input features. Only features that interact with the bounding box are returned.
If all four coordinates of the search envelope are specified as 0, the search envelope will be disabled.
Mapping File Syntax
<ReaderKeyword>_SEARCH_ENVELOPE <minX> <minY> <maxX> <maxY>
Note: If all four coordinates of the search envelope are specified as zero, the search envelope will be disabled.
Required/Optional
Optional
Workbench Parameter
Minimum X, Minimum Y, Maximum X, Maximum Y
SEARCH_ENVELOPE_COORDINATE_SYSTEM
This directive specifies the coordinate system of the search envelope if it is different than the coordinate system of the data.
The COORDINATE_SYSTEM
directive, which specifies the coordinate system associated with the data to be read, must always be set if the SEARCH_ENVELOPE_COORDINATE_SYSTEM
directive is set.
If this directive is set, the minimum and maximum points of the search envelope are reprojected from the SEARCH_ENVELOPE_COORDINATE_SYSTEM
to the reader COORDINATE_SYSTEM
prior to applying the envelope.
Required/Optional
Optional
Mapping File Syntax
<ReaderKeyword>_SEARCH_ENVELOPE_COORDINATE_SYSTEM <coordinate system>
Workbench Parameter
Search Envelope Coordinate System
CLIP_TO_ENVELOPE
This directive specifies whether or not FME should clip features to the envelope specified in the SEARCH_ENVELOPE
directive.
Values
YES | NO (default)
Mapping File Syntax
<ReaderKeyword>_CLIP_TO_ENVELOPE [yes | no]
Workbench Parameter
Clip To Envelope
EXPOSED_ATTRS
This directive allows the selection of format attributes to be explicitly added to the reader feature type.
This is similar to exposing format attributes on a reader feature type once it has been generated; however, it is even more powerful because it enables schema-driven applications other than Workbench to access and leverage these attributes as if they were explicitly on the schema as user attributes.
The result of picking a list of attributes is a comma-separated list of attribute names and types that will be added to the schema features. Currently all reader feature types will receive the same set of additional schema attributes for a given instance of the reader.
Required/Optional
Optional
Mapping File Syntax
Not applicable.
While it is possible for FME Objects applications to invoke this directive, the required format is not documented.
This directive is intended for use in our GUI applications (for example, Workbench) only.
Workbench Parameter
Additional Attributes to Expose
RETRIEVE_ALL_SCHEMAS
This parameter is applicable only when generating a mapping file, generating a workspace, or when retrieving schemas in an FME Objects application.
When set to yes, schemas for all of the tables and feature classes in the database are returned.
When set to no (or missing), and if RETRIEVE_ALL_TABLE_NAMES
is similarly set to no (or missing), only schemas requested by the IDs parameter are returned.
Required/Optional
Optional
Values
YES | NO (default)
NO: The reader will return the schemas for the feature types specified in the IDs. If no features are specified in IDs, then:
- for Enterprise Geodatabases, FME will not return any schema features;
- for Personal and File Geodatabases, FME returns the schema features for all the tables.
If this value is not specified, then it is assumed to be No.
YES: Indicates to the reader to return all the schemas of the tables in the database.
Mapping File Syntax
Not applicable.
FME Objects applications would include RETRIEVE_ALL_SCHEMAS
followed by “YES” in the parameters array passed to IFMEUniversalReader::open()
.
Workbench Parameter
Not applicable
RETRIEVE_ALL_TABLE_NAMES
This parameter is only applicable when generating a mapping file, generating a workspace or when retrieving schemas in an FME Objects application.
When set to yes, and if RETRIEVE_ALL_SCHEMAS
is set to no (or missing), names for all of the tables and feature classes in the database are returned. When set to no (or missing), and if RETRIEVE_ALL_SCHEMAS
is similarly set to no (or missing), the schemas requested by the IDs directive are returned.
Note: If RETRIEVE_ALL_SCHEMAS is also set to Yes, then RETRIEVE_ALL_SCHEMAS takes precedence.
Required/Optional
Optional
Values
YES | NO (default)
Mapping File Syntax
Not applicable.
FME Objects applications would include RETRIEVE_ALL_TABLE_NAMES
followed by “YES” in the parameters array passed to IFMEUniversalReader::open()
.
Workbench Parameter
Not applicable (used when you browse a Table List)