FME Transformers: 2024.1
FME Transformers: 2024.1
JMSSender
Using the Java Message System (JMS), sends messages to a message broker.
Working with JMS
For information about configuring FME to communicate with JMS-compliant message brokers, see Working with JMS.
Usage Notes
The performance of this transformer is dependent on the amount of memory allocated to the Java Virtual Machine (JVM). The following environment variables allow you to specify memory available to Java Plugins:
- FME_JVM_MIN_HEAP_SIZE: Initial heap size for initializing the JVM. If unset, the default value is 1024K.
These variables must be set in multiples of 1024 and greater than 1 MB. To indicate kilobytes, megabytes, or gigabytes, append k or K, m or M, or g or G respectively. For example, any of these values is acceptable:
6291456
6144k
6m
- FME_JVM_MAX_HEAP_SIZE: Maximum heap size for initializing the JVM. If unset, the default value is 16384K.
These variables must be set in multiples of 1024 and greater than 2 MB. To indicate kilobytes, megabytes, or gigabytes, append k or K, m or M, or g or G respectively. For example, any of these values is acceptable:
83886080
81920k
80m
Note To pass additional parameters used by FME to the Java Virtual Machine, use the JAVA_TOOL_OPTIONS environment variable.
Configuration
Parameters
Connection
Provider Type or Context |
The message broker to connect to, or the initial context factory if the broker is not listed. |
Provider URL |
The URL of the folder containing connection details for the JMS provider. |
Additional Provider Properties |
Any additional provider-specific properties, in the form key=value. Specify multiple pairs on separate lines, using the Text Editor. In most cases, this field is not required. The JMS brokers tested by Safe, including Apache ActiveMQ, IBM Websphere MQ, and Oracle WebLogic JMS, do not require any additional properties to establish a connection. Note When connecting to ACTIVEMQ, do not specify any failover transport options here. Instead, specify them directly in the Provider URL field. For example:
failover:(tcp://primary:61616,tcp://secondary:61616)?randomize=false |
Connection Factory |
The name of the connection factory object. |
Username |
An authenticating username. |
Password |
An authenticating password. |
Destination(s) |
The names of the destination objects. These correspond to queues and/or topics. |
Message
Message Attribute |
The attribute that contains the message to send. |
Use Persistent Delivery |
If Yes, messages are stored by the JMS broker until the message is delivered to a destination, and can be recovered in the event of a broker restart. If No, messages may be lost in the event of a broker restart during delivery. Persistent delivery is slower than non-persistent delivery, particularly when sending large volumes of messages. |
Editing Transformer Parameters
Transformer parameters can be set by directly entering values, using expressions, or referencing other elements in the workspace such as attribute values or user parameters. Various editors and context menus are available to assist. To see what is available, click beside the applicable parameter.
How to Set Parameter Values
Defining Values
There are several ways to define a value for use in a Transformer. The simplest is to simply type in a value or string, which can include functions of various types such as attribute references, math and string functions, and workspace parameters.
Using the Text Editor
The Text Editor provides a convenient way to construct text strings (including regular expressions) from various data sources, such as attributes, parameters, and constants, where the result is used directly inside a parameter.
Using the Arithmetic Editor
The Arithmetic Editor provides a convenient way to construct math expressions from various data sources, such as attributes, parameters, and feature functions, where the result is used directly inside a parameter.
Conditional Values
Set values depending on one or more test conditions that either pass or fail.
Parameter Condition Definition Dialog
Content
Expressions and strings can include a number of functions, characters, parameters, and more.
When setting values - whether entered directly in a parameter or constructed using one of the editors - strings and expressions containing String, Math, Date/Time or FME Feature Functions will have those functions evaluated. Therefore, the names of these functions (in the form @<function_name>) should not be used as literal string values.
Content Types
These functions manipulate and format strings. | |
Special Characters |
A set of control characters is available in the Text Editor. |
Math functions are available in both editors. | |
Date/Time Functions | Date and time functions are available in the Text Editor. |
These operators are available in the Arithmetic Editor. | |
These return primarily feature-specific values. | |
FME and workspace-specific parameters may be used. | |
Creating and Modifying User Parameters | Create your own editable parameters. |
Dialog Options - Tables
Table Tools
Transformers with table-style parameters have additional tools for populating and manipulating values.
Row Reordering
|
Enabled once you have clicked on a row item. Choices include:
|
Cut, Copy, and Paste
|
Enabled once you have clicked on a row item. Choices include:
Cut, copy, and paste may be used within a transformer, or between transformers. |
Filter
|
Start typing a string, and the matrix will only display rows matching those characters. Searches all columns. This only affects the display of attributes within the transformer - it does not alter which attributes are output. |
Import
|
Import populates the table with a set of new attributes read from a dataset. Specific application varies between transformers. |
Reset/Refresh
|
Generally resets the table to its initial state, and may provide additional options to remove invalid entries. Behavior varies between transformers. |
Note: Not all tools are available in all transformers.
For more information, see Transformer Parameter Menu Options.
FME Community
The FME Community is the place for demos, how-tos, articles, FAQs, and more. Get answers to your questions, learn from other users, and suggest, vote, and comment on new features.
Search for all results about the JMSSender on the FME Community.