FME Flow: 2024.2
Starting and Stopping FME Flow Manually
Although the FME Flow System Services start automatically, you can start and stop the services manually in the following ways:
- From the Services window (the procedure for accessing the services may vary by Windows version):
Control Panel > Administrative Tools > Services
Or
Start > Run > services.msc
In the Services window, select one or more of the services, and start or stop as required.
Linux scripts for starting and stopping FME Flow are located in:
<FMEFlowDir>/Server/
Although you can configure FME Flow to start automatically, you can start it manually by running startServer.sh as the root user.
This script starts all the FME Flow System Services in the necessary order. Alternatively, to start each service individually, run the following scripts, located in the same directory:
startCore.sh
: FME Flow Core servicestartEngines.sh
: FME EnginesstartDatabaseServer.sh
: FME Flow DatabasestartApplicationServer.sh
: FME Flow Application ServerstartWebSocketServer.sh
: FME Flow WebSocket ServerstartCleanup.sh
: FME Flow Cleanup servicestartRootServices.sh
- Starts all the services that run as the root user. This script callsstartWebSocketServer.sh
,startCleanup.sh
, andstartApplicationServer.sh
.
To stop FME Flow, run stopServer.sh as the root user.
Alternatively, stop the services individually with these scripts:
stopCore.sh
stopEngines.sh
stopDatabaseServer.sh
stopApplicationServer.sh
stopWebSocketServer.sh
stopCleanup.sh
stopRootServices.sh
What Happens to Jobs After a Manual Restart?
When FME Flow is restarted, the behavior of jobs that are in a Running or Queued state depends on how the jobs were submitted:
|
|||||
---|---|---|---|---|---|
Full Restart | Running jobs are resubmitted to the queue. Queued jobs run before resubmitted jobs. | Running jobs fail and are not resubmitted.* Queued jobs run once the FME Flow services are running. | Running jobs are resubmitted to the queue. The job ID may change depending on availability of FME Engines. | ||
FME Engines Restart | |||||
Core Restart | |||||
Database Restart | |||||
Web Application Server Restart | Jobs continue to run as the FME Engines process the job queue. |
* If Retry on Failure was checked on the workspace action of an automation, the job is resubmitted based on the Retry settings once the FME Flow services are running.
A resubmitted job has the same ID as its initial run, and assumes the job_<ID>.log filename. Logs for previous submissions of the same job can be accessed in the same folder. For more information, see FME Job Logs and About Log Files in FME Flow.