FMEServerJobWaiter
Waits until submitted FME jobs are started or finished by an FME Server. The list of jobs to wait for is identified by the job IDs of the input features. When a job that the transformer is waiting for starts or completes, it outputs the corresponding feature immediately.
Note: This transformer should not be used if your FME Server has only one engine.
Dependencies
This transformer requires an FME Server connection.
Output Ports
The initiating feature is output via the Output port if the job successfully ran to completion, and will have these attributes added to it:
- _job_id: the integer ID the server assigned to this job
- _numFeaturesOutput: the number of features that were output by the job
- _priority: the priority assigned to the job
- _requesterHost: the name of the machine through which results are returned
- _requesterResultPort: the port on the machine through which results are returned
- _status: job status indicator; if waiting for job to start, it can be SUCCESS or PULLED; if waiting for job to finish, it is SUCCESS
- _statusMessage: the translation result message
- _timeFinished: the time the job finished
- _timeRequested: the time the server received the job request
- _timeStarted: the time the server started processing the job
All times are in YYYYMMDDhhmmss format.
The feature will be output via the <Rejected> port if the job either did not run to completion, or the server could not be contacted, and will have these attributes added to it:
- _failure_reason: the reason when unable to wait for a job
- _http_status_code: the HTTP status code when unable to wait for a job
- _job_id: the integer ID the server assigned to this job
- _numFeaturesOutput: the number of features that were output by the job
- _priority: the priority assigned to the job
- _requesterHost: the name of the machine through which results are returned
- _requesterResultPort: the port on the machine through which results are returned
- _status: job status indicator; it can be ABORTED, FME_FAILURE, or JOB_FAILURE
- _statusMessage: the error message returned from the server explaining why the request failed
- _timeFinished: the time the job finished
- _timeRequested: the time the server received the job request
- _timeStarted: the time the server started processing the job
All times are in YYYYMMDDhhmmss format.
Connection
You can connect to an FME Server in one of the following ways:
Specify a web connection to an FME Server. Web connections can be reused in multiple workspaces, and connection parameters are hidden in the workspace. For more information, see Using Web Connections.
When checked, you must specify the connection parameters to the FME Server manually. The connection parameters are visible in the workspace. To connect, specify:
Enter a URL to access FME Server. You may need to contact your System Administrator for the URL.
Provide your FME Server credentials.
Note: You can click the Status hyperlink to ensure that the FME Server connection has been successfully established.
Parameters
Specifies whether to wait for a job to Complete or Start.
The list of jobs to wait for is identified by the job IDs of the input features. When a job that it is waiting for starts or completes, it outputs the corresponding feature immediately.
The time interval for this transformer to wait between inquiries into the status of each job is specified by the Polling Interval. This is measured in seconds and can be entered as an integer value or an integer attribute.
Note: You should use as large value as possible for this parameter. If it is set too small, it not only impacts the resources on the client, but also on the FME Server responding to each query. For example, if the job is expected to take about 20 minutes, then it is not efficient to set the Polling Interval to a few seconds.
Editing Transformer Parameters
Using a set of menu options, transformer parameters can be assigned by referencing other elements in the workspace. More advanced functions, such as an advanced editor and an arithmetic editor, are also available in some transformers. To access a menu of these options, click beside the applicable parameter. For more information, see Transformer Parameter Menu Options.
Defining Values
There are several ways to define a value for use in a Transformer. The simplest is to simply type in a value or string, which can include functions of various types such as attribute references, math and string functions, and workspace parameters. There are a number of tools and shortcuts that can assist in constructing values, generally available from the drop-down context menu adjacent to the value field.
Using the Text Editor
The Text Editor provides a convenient way to construct text strings (including regular expressions) from various data sources, such as attributes, parameters, and constants, where the result is used directly inside a parameter.
Using the Arithmetic Editor
The Arithmetic Editor provides a convenient way to construct math expressions from various data sources, such as attributes, parameters, and feature functions, where the result is used directly inside a parameter.
Conditional Values
Set values depending on one or more test conditions that either pass or fail.
Parameter Condition Definition Dialog
Content
Expressions and strings can include a number of functions, characters, parameters, and more.
When setting values - whether entered directly in a parameter or constructed using one of the editors - strings and expressions containing String, Math, Date/Time or FME Feature Functions will have those functions evaluated. Therefore, the names of these functions (in the form @<function_name>) should not be used as literal string values.
These functions manipulate and format strings. | |
Special Characters |
A set of control characters is available in the Text Editor. |
Math functions are available in both editors. | |
Date/Time Functions | Date and time functions are available in the Text Editor. |
These operators are available in the Arithmetic Editor. | |
These return primarily feature-specific values. | |
FME and workspace-specific parameters may be used. | |
Creating and Modifying User Parameters | Create your own editable parameters. |
Dialog Options - Tables
Transformers with table-style parameters have additional tools for populating and manipulating values.
Row Reordering
|
Enabled once you have clicked on a row item. Choices include:
|
Cut, Copy, and Paste
|
Enabled once you have clicked on a row item. Choices include:
Cut, copy, and paste may be used within a transformer, or between transformers. |
Filter
|
Start typing a string, and the matrix will only display rows matching those characters. Searches all columns. This only affects the display of attributes within the transformer - it does not alter which attributes are output. |
Import
|
Import populates the table with a set of new attributes read from a dataset. Specific application varies between transformers. |
Reset/Refresh
|
Generally resets the table to its initial state, and may provide additional options to remove invalid entries. Behavior varies between transformers. |
Note: Not all tools are available in all transformers.
Transformer History
This transformer was previously named the ServerJobWaiter.
FME Community
The FME Community is the place for demos, how-tos, articles, FAQs, and more. Get answers to your questions, learn from other users, and suggest, vote, and comment on new features.
Search for samples and information about this transformer on the FME Community.
Keywords: ServerJobWaiter