WebSocketReceiver

Receives WebSocket messages from the specified WebSocket server. Produces a feature each time a message is received, and places the contents of the message into the specified attribute. Each incoming feature will cause the WebSocketReceiver to initialize a connection to the specified WebSocket server. The transformer will block while it waits to receive WebSocket messages until the remote host closes the connection.

Usage Notes

The performance of this transformer is dependent on the amount of memory allocated to the Java Virtual Machine (JVM). The following environment variables allow you to specify memory available to Java Plugins:

  • FME_JVM_MIN_HEAP_SIZE: Initial heap size for initializing the JVM. If unset, the default value is 1024K.
  • FME32_JVM_MIN_HEAP_SIZE: Same as FME_JVM_MIN_HEAP_SIZE, but applies to 32-bit FME Desktop on Windows, and if set, takes precedence over FME_JVM_MIN_HEAP_SIZE.

These variables must be set in multiples of 1024 and greater than 1 MB. To indicate kilobytes, megabytes, or gigabytes, append k or K, m or M, or g or G respectively. For example, any of these values is acceptable:

6291456

6144k

6m

  • FME_JVM_MAX_HEAP_SIZE: Maximum heap size for initializing the JVM. If unset, the default value is 16384K.
  • FME32_JVM_MAX_HEAP_SIZE: Same as FME_JVM_MAX_HEAP_SIZE, but applies to 32-bit FME Desktop on Windows, and if set, takes precedence over FME_JVM_MAX_HEAP_SIZE.

These variables must be set in multiples of 1024 and greater than 2 MB. To indicate kilobytes, megabytes, or gigabytes, append k or K, m or M, or g or G respectively. For example, any of these values is acceptable:

83886080

81920k

80m

Note: To pass additional parameters used by FME to the Java Virtual Machine, use the JAVA_TOOL_OPTIONS environment variable.

Input Ports

Output Ports

Parameters

Editing Transformer Parameters

Using a set of menu options, transformer parameters can be assigned by referencing other elements in the workspace. More advanced functions, such as an advanced editor and an arithmetic editor, are also available in some transformers. To access a menu of these options, click beside the applicable parameter. For more information, see Transformer Parameter Menu Options.

Defining Values

There are several ways to define a value for use in a Transformer. The simplest is to simply type in a value or string, which can include functions of various types such as attribute references, math and string functions, and workspace parameters. There are a number of tools and shortcuts that can assist in constructing values, generally available from the drop-down context menu adjacent to the value field.

Dialog Options - Tables

Transformers with table-style parameters have additional tools for populating and manipulating values.

FME Licensing Level

FME Professional edition and above

FME Community

The FME Community is the place for demos, how-tos, articles, FAQs, and more. Get answers to your questions, learn from other users, and suggest, vote, and comment on new features.

Search for samples and information about this transformer on the FME Community.