SNSSender
Using the Amazon Simple Notification Service (SNS), sends messages to an Amazon SNS topic.
Usage Notes
The performance of this transformer is dependent on the amount of memory allocated to the Java Virtual Machine (JVM). The following environment variables allow you to specify memory available to Java Plugins:
- FME_JVM_MIN_HEAP_SIZE: Initial heap size for initializing the JVM. Default value is 1024K.
-
FME32_JVM_MIN_HEAP_SIZE: Same as FME_JVM_MIN_HEAP_SIZE, but applies to the 32-bit version of FME Desktop on Windows, and takes precedence over FME_JVM_MIN_HEAP_SIZE.
- FME_JVM_MAX_HEAP_SIZE: Maximum heap size for initializing JVM. Default value is 16384K.
-
FME32_JVM_MAX_HEAP_SIZE: Same as FME_JVM_MAX_HEAP_SIZE, but applies to the 32-bit version of FME Desktop on Windows, and takes precedence over FME_JVM_MAX_HEAP_SIZE.
If unset, the JVM applies the default values. If set, the values must be multiples of 1024K (for example, 4M and 64M, or 4096K and 32768K).
Note: To pass additional parameters used by FME to the Java Virtual Machine, use the JAVA_TOOL_OPTIONS environment variable.
Input Ports
This transformer accepts any feature.
Output Ports
This transformer has no output ports.
Parameters
Amazon Simple Notification Service Parameters
The Amazon Resource Name (ARN) of the topic where messages are to be sent.
An access key associated with a user with permission to send messages to the topic.
A secret key paired with the access key provided.
Message Parameters
The attribute containing the message to be sent.
The attribute containing the subject of the message to be sent.
Working with SNS
For more information about sending messages using the Simple Notification Service (SNS), see the Amazon Simple Notification Service Subscriber in the FME Server Reference Manual.
Editing Transformer Parameters
Using a set of menu options, transformer parameters can be assigned by referencing other elements in the workspace. More advanced functions, such as an advanced editor and an arithmetic editor, are also available in some transformers. To access a menu of these options, click beside the applicable parameter. For more information, see Transformer Parameter Menu Options.
Transformer Categories
FME Licensing Level
FME Professional edition and above